Serial Input Connector

Prev Next

Param name

Mandatory

Description

Default Value

Possible Value

PortName

Yes

COM port where the automation system resides.

COM3

Any valid COM port name (varies).

BaudRate

Yes

Baud rate at which to establish the connection.

9600

4800, 9600, 19200, 38400, 57600, 115200, 230400.

Parity

Yes

Parity of the connection.

Even

None, Odd, Even, Mark, Space.

DataBits

Yes

Number of data bits per byte.

8

5 - 8

StopBits

Yes

Number of stop bits.

One

None, One, OnePointFive, Two

Handshake

Yes

Handshaking protocol for serial port transmission of data.

None

None, RequestToSend, RequestToSendXOnXOff, XOnXOff.

DeadAirTimeout

No

If specified, defines a timeout period between the reception of data after which the input connector is reset.

n/a

1 - 2,147,483,647

Example XML:

<SerialInputConnector>
   <PortName>COM3</PortName>
   <BaudRate>9600</BaudRate>
   <Parity>Even</Parity>
   <DataBits>8</DataBits>
   <StopBits>None</StopBits>
   <Handshake>None</Handshake>
   <DeadAirTimeout>600</DeadAirTimeout>
   <Relays>
     <LogFileRelay>
       <FilesToKeep>10</FilesToKeep>
     </LogFileRelay>
     <TcpServerRelay>
       <Port>12834</Port>
     </TcpServerRelay>
   </Relays>
</SerialInputConnector>